Loading...
HomeMy WebLinkAboutSEP1980-00031 i L04 11)— GA fiGT f/ ' Include the following items on your plot.pianc. .,. a Property boundaries a Wells o Names of adjacent streets CI Septic tank o Driveways and parking spaces a Drainfield(enter NN if unkno*R 3 „ a Surface water(ponds,creeks,etc) a North Arrow a u 2015 0 Buildings(residence,sheds,garages, etc) ' ,r1! Periitt, PLOT PLAN-date prepared ' ' il As 5e---Mi -77,--is 6y cviz_ce- pvist 4T Al r----4/.627 664,/14 /-4-04,...7-,,,e. . ) #.1-1-71-;:(2- bbi TO gc/L7LE-- ,... . 6fritigoE . 3 6W-rocim )461/56-- , SErac, ' 0 4--. •Nic Dai-lat) F I Elf) -----') cr pad) ,ry i S 14 OP IC, _ ---,, \ Permit#or Parcel# (3021 I rt ( 055 51 gO "6063 I Evaluation of an Existing Onsite Sewage System_07130/04_ud1 3/26/2015 Goodman,Inc 2495 Cape George Rd 360-385-7155 Port Townsend, WA 98368 PROPERTY INFORMATION • House Location:3135 OAK BAY RD AR 3 0 2015 Port Hadlock Tax ID:921191035 Mail To: Chris Malan 6127 Canyon Creek Lane Use:Residential,Single Family Conroe,TX COpV System Design Flow:240 77304 GENERAL SYSTEM TYPE:Gravity Owner:Chris Malan ON ID:SOM80-00031 Fold ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold Here Inspected:03/25/2015 - Inspection Type:FOLLOW UP - Correction Status:All corrections made Here Company: Certification-Level 1 Work Performed By: Submitted 0326/2015 by: Goodman, Inc. Orville Wise Doug Nebel This report does not assure approvals by Jefferson County Public Health for ANY future building permits or development. COMMENTS&GENERAL INSPECTION NOTES No Deficiencies Noted GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected All Components accessible for maintenance,secure and in good condition: YES Surfacing effluent from any component(including mound seepage): NO Components appear to be watertight-no visual leaks: YES Improper encroachment(roads,buildings,etc.)onto component(s): NO Component settling problems observed: NO Abnormal ponding present for one or more of the disposal components: _ NO Subsurface components adequately covered YES Owner compliance issues noted NO Site maintenance required(e.g.Landscape maintenance)If yes,describe in comments: _ NO Occupant compliance problem(occupant not operating the system properly). If YES,describe in notes: NO If deficiencies were identified on last inspection were they corrected before or during this inspection? YES (If NO,describe in notes,NA=no deficiencies on last report): OSS Components,structures and appurtenances located per as-built/record drawing(If NO,describe YES in notes). If no as-built exists or changes made,state NO and provide record to Health Dept: Alterations made to the OSS(valves adjusted,timer settings modified,ports installed,etc.)(If YES, NO describe in notes): The house/structure was vacant or used infrequently,assessment of the drainfield was not possible. NO Is the SEP case in a finaled/completed status?(if NO explain in comments) YES ONSITE SEWAGE SYSTEM INSPECTION DETAIL ANK:Septic Tank-2 Compartment 1,000 gal This component was: Fully Inspected Component appears to be functioning as intended: YES Effluent level within operational limits(if NO explain in comments): YES All required baffles in place(N/A=No baffles required): YES Effluent Filter Cleaned(N/A=Not Present): N/A Compartment 1 Scum accumulation(Inches,if other specify): Effluent filter/screen needed cleaning on arrival N/A Compartment 1 Sludge accumulation(Inches,if other specify): 2 Compartment 2 Scum accumulation(Inches,if other specify): 0 Compartment 2 Sludge accumulation(Inches,if other specify): o Pumping needed: NO Approximate Gallons to be pumped(if needed)by Certified Pumper: ReportlD:429788 View inspection reports online at www.onlinerme.com Page 1 of 2 grainfield:Gravity Fully Inspected This component was: Component appears to be functioning as intended: YES Ponding present?If YES explain in comments: NO This report indicates certain characteristics of the onsite sewage system at the time of visit.In no way is this report a guarantee of operation or future performance. ReportiD:429788 View inspection reports online at www.onlinerme.cam Page 2 of 2 ,/777Kt'/1/1 t / '/ '1 SEP 8D - 0OD3L Now filed to SEP