Loading...
HomeMy WebLinkAboutBLD2000-00174 Geotechnical Report • • G.JOTECHNICAL TESTING LABORATORY J^SEPH u ,;^A-N-OEL 162 HILLER$R. HADLOCK,TWA 98339 Re: Foundation o'home -Soils compaction Gentlemen: As requested, compaction tests were conducted on-the subgrade for the foundation ofthe home. All test results exceeded 90%--of the maximumdry density as--based-on-our-proctor analysis according-to--ASTM-D 1557. The subgrade can be considered ready for the placement of the mobile home. The proctor and test results are enclosed. Thank you for this opportunity to be of service to you. Respectfully-Submitted, GEOTECHNICAL TESTINGLABORATORY Harold Parks, Engineering Geologist cc : Washington Home Center fp MAY 0 s 2000 10011 Blomberg Street-SW,Olympia,WA 98512 Phone#: (360)754-4612 Fax#: (360)754-4848 GEQTECRNICAL_ TESTING LABORATORY JOSEPH& JOAN NOEL 162 HILLER DR. HADLOCK, WA Re: - 1n-Place-Density Test-Report performed on 5/6/00 Project::- 162-Hiller Dr.,.Hadlock Inspector: Hal Parks Gentlemen: As requested, Geotechnical Testing Lab perform on-site density testing in accordance with current applicable standards. The results obtained were as-follows: Test Test Percent Dry Material Percent Percent Location _ Moisture Density Type Compaction Required I See Plan 3.9 116.7 A 90.8 90 2 4.2 1 kl.4 91.3 Material Type: A: 128.5 @ 5.1%well graded gravel with sand If you have any-questions concerning the test results,the procedures.used,or if we can be of any further assistance please call on us at(360)754-4612 Respectfully-Submitted=, GEOTECHNICAL TESTING LABORATORY .kail-00 f 10 Harold Parks, Engineering Geologist 10011 Blomberg Street SW,Olympia,WA 98512 Phone#: (360)754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY SITE PLAN WITH TEST LOCATIONS 162 Hiller Dr . Hadlock, WA water water 5-6-00 Hiller Dr . Ni #1 #2 (.; 0 uci,A) gr, rd a) N '4Pve c2-1 . „. . . . . . . . . . .„ . . MINNIMMIM•11011=MIIMMOOMMIMMMEIMMIMEMINIMMIOW 10011 Blomberg,Street SW, Olympia, WA 98512 t a c Geotechnical Testing Lab Date Received: 5/7/00 Sample ID: Wash.Home Center Quarry Rock Sieve Size Specifications Sample#: 1 Source:Hadlock US mm Max Min ASTM D-2A87,Unified Soils Classification System 6.00" 150.0 100.0% 0.0% GW,Well-graded Gravel with Sand 4.00" 100.0 100.0% 0.0°/ Sample Prepared: Moist X Manual:X 3.00" 75.0 100.0% 0.0°/ Dry: Mechanical: 2.50" 63.0 100.0% 0.0% Test Standard: AASHTO T 99: AASHTO T 180: Method 2.00" 50.0 88.0% 100.0% 0.0°/ ASTM D 698: ASTM D 1557:X C 1.75" 45.0 100.0% 0.0°/ 1.50" 37.5 100.0% 0.0°/ Assumed Sp.Gr. Point Percent Dry Maximum Optiimu II 1.25" 31.5 100.0% 0.0°/ 2.70 Number Moisture Density Dry Density %Moistur• 1.00" 25.0 100.0% 0.0°/ 1 2.4% 126.2 128.5 lbs/ft3 Si% 7/8" 22.4 100.0% 0.0% 2 3.1% 127.4 3/4" 19.0 71.0% 100.0% 0.0°/ 3 4.5% 128.3 5/8" 16.0 100.0% 0.0% 4 6.2% 128.1 1/2" 12.5 100.0% 0.0°/ 3/8" 9.5 63.0% 100.0% 0.0°/ 1/4" 6.3 100.0% 0.0°/ Moisture Density Relationship Zero Air VO1ds #4 4.750 37.0% 100.0% 0.0% r30.° . ,- ., #8 2.360 100.0% 0.0% #10 2.000 100.0% 0.0% 128.0- -- #16 1.180 100.0% 0.0°/ #20 0.850 100.0% 0.0°/ A 126.0-- - #30 0.600 100.0% 0.0°/ ?-' lily Deity #40 0.425 9.0% 100.0% 0.0% Ca 124.0•- #50 0.300 100.0% 0.0°/ #60 0.250 100.0% 0.0°/ lzzn t t . #80 0.180 100.0% 0.0°/ 2% 3% 4% 5% 6% 7% 8% #100 0.150 100.0% 0.0% Percent Moisture #140 0.106 100.0% 0.0°/ • Data Points Zero Air Voids Curve Curve Fit #170 0.090 100.0% 0.0°/ 4i #200 0.075 1.0% 100.0% 0.0°/ .pets: Meets Specs?Yes No Specs ASTM D-4718,Correction for Oversize Particles %Retained 3/4"29.0% %Retained Corrected Optimum %Retained Corrected Optimum %Gravel:63.0% Dt101: 0.579 I 3/4"Sieve Density Moisture 3/4"Sieve Density Moisture %Sand: 36.0% D(301:• 3.669 5% 130.0 4.9% 20% 134.9 4.2% %Silt&Clav: 1.0% D(60): 8.952 10% 131.6 4.6% 25% 136.6 4.0% Cc:2.59 LL:0.0% 15% 133.2 4.4% 30% 138.3 3.7% Cu: 15.45 PL: 0.0% FM: 5.93 PI: 0.0% Copyright Spears P.gio eying&Technical Services PS,1996-98